    基于二步法的多芯電纜非侵入式電流測量校正方法

    宋憲 張勇軍 寧貝飛 汪偉

    宋憲, 張勇軍, 寧貝飛, 汪偉. 基于二步法的多芯電纜非侵入式電流測量校正方法[J]. 工程科學學報, 2017, 39(12): 1898-1906. doi: 10.13374/j.issn2095-9389.2017.12.017
    引用本文: 宋憲, 張勇軍, 寧貝飛, 汪偉. 基于二步法的多芯電纜非侵入式電流測量校正方法[J]. 工程科學學報, 2017, 39(12): 1898-1906. doi: 10.13374/j.issn2095-9389.2017.12.017
    SONG Xian, ZHANG Yong-jun, NING Bei-fei, WANG Wei. Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation[J]. Chinese Journal of Engineering, 2017, 39(12): 1898-1906. doi: 10.13374/j.issn2095-9389.2017.12.017
    Citation: SONG Xian, ZHANG Yong-jun, NING Bei-fei, WANG Wei. Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation[J]. Chinese Journal of Engineering, 2017, 39(12): 1898-1906. doi: 10.13374/j.issn2095-9389.2017.12.017

    基于二步法的多芯電纜非侵入式電流測量校正方法

    doi: 10.13374/j.issn2095-9389.2017.12.017
    詳細信息
    • 中圖分類號: TP212.13

    Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation

    • 摘要: 為了解決多芯電纜的非侵入式電流測量由于被測對象信號微弱、系統靈敏度高、易受環境因素干擾,造成測量誤差較大的問題,采用磁阻傳感器的非侵入式電流測量系統為研究對象,在分析系統測量方法及硬鐵、軟鐵和比例因子等誤差構成的基礎上,提出一種基于二步法的誤差校正方法,該方法通過對傳感器輸出信號進行非線性變換,構造了與誤差相對應的矩陣方程,并在對方程求解后進行非線性回歸計算,從而實現對多芯電纜的電流測量值的動態誤差修正.實驗結果表明,該方法可以同時校正非侵入式電流測量系統的線性誤差與部分非線性誤差.

       

    • [1] Paul C R. Analysis of Multiconductor Transmission Lines. Hoboken:John Wiley & Sons, 2008
      [4] Brauer J R. Magnetic Actuators and Sensors. 2nd Ed. Piscataway:IEEE press, 2013
      [5] Tumanski S. Induction coil sensors-a review. Meas Sci Technol, 2007, 18(3):R31
      [9] Meng L C, Gao P F, Haji M M, et al. Magnetic sensor arraybased AC current measurement for multiconductor cables using evolutionary computation method. IEEE T Instrum Meas, 2015, 64(10):2747
      [10] Olson E R, Lorenz R D. Effectiveuse of miniature multipoint field-based current sensors without magnetic cores. IEEE T Ind Appl, 2010, 46(2):901
      [11] Erlewein P. Development of a Non-Invasive Measurement Application for Power Cables Using the Magnetoresistive Effect[Dissertation]. Karlsruhe:Karlsruhe University of Applied Science, 2012
      [12] Pylvänäinen T. Automatic and adaptive calibration of 3D field sensors. Appl Math Model, 2008, 32(4):575
      [13] Bluemm C, Weiss R, Weigel R, et al. Correcting nonlinearity and temperature influence of sensors through B-spline modeling//2010 IEEE International Symposium on Industrial Electronics (ISIE). Bari, 2010:3356
      [15] Gebre-Egziabher D, Elkaim G H, David Powell J, et al. Calibration of strapdown magnetometers in magnetic field domain. J Aerospace Eng, 2006, 19(2):87
      [16] Zhang Z Q. Two-step calibration methods for miniature inertial and magnetic sensor units. IEEE T Ind Electron, 2015, 62(6):3714
      [17] Huang Y, Wu L H. Two-step complete calibration of magnetic vector gradiometer based on functional link artificial neural network and least squares. IEEE Sens Jl, 2016, 16(11):4230
      [18] Foster C C, Elkaim G H. Extension of a two-step calibration methodology to include nonorthogonal sensor axes. IEEE T Aerospace Electron Syst, 2008, 44(3):1070
      [19] Madgwick S O H, Harrison A J L, Vaidyanathan R. Estimation of IMU and MARG orientation using a gradient descent algorithm//IEEE International Conference on Rehabilitation Robotics. Zurich, 2011:1
      [20] Fang J C, Sun H W, Cao J J, et al. A novel calibration method of magnetic compass based on ellipsoid fitting. IEEE T Instrum Meas, 2011, 60(6):2053
    • 加載中
    計量
    • 文章訪問數:  692
    • HTML全文瀏覽量:  220
    • PDF下載量:  16
    • 被引次數: 0
    出版歷程
    • 收稿日期:  2017-01-12

    目錄

      /

      返回文章
      返回
      中文字幕在线观看